whatsapp
Brand KRYKARD UPS System On Line UPS KRYKARD Make 3 KVA 1:1 Phase On-Line UPS with Inbuilt Batteries

KRYKARD Make 3 KVA 1:1 Phase On-Line UPS with Inbuilt Batteries

ELB 11-03

UPS System On Line UPS

Price: 35282

You save 17204.4

  • From India’s Most Trusted Power Conditioning Brand Quality and Service support are key USPs for all KRYKARD products
  • High frequency on-line double conversion
  • DSP (Digital signal processors) control
  • Active power factor correction (APFC), input power factor up to 0.99
  • Output power factor @0.9
  • Wide input voltage range of 110 V - 300 Vac
  • Linear load derating for input voltages under 176V to reduce battery usage
  • Wide input frequency range of 40 - 70 Hz
  • 50/60 Hz and 60/50 Hz frequency conversion feature

  • Reset default

    Specification

    Output Specification
    Output Capacity (KVA )
    3 KVA
    Output Capacity (KW )
    2.7 KW
    Output Power Factor
    0.9 Power Factor
    Output Phase
    1 Or Phase
    Other Output Phase
    1 Or Phase
    Output Voltage
    240 Volt
    Other Output Voltage
    208 Or 240 Volt
    Efficiency at Full Load
    > 90 %
    Output Voltage Distortion
    < 2 %
    Output Frequency (sync to mains)
    50/60Hz +/- 3 Hz
    Output Frequency (not synced)
    +/- 0.1% for 50/60Hz Nominal
    Load Crest Factor
    3:1
    Output Voltage THD
    < %
    Transfer Time
    < 0 ms
    Output Waveform type
    Sine Wave
    Bypass
    Internal Bypass (automatic & manual)
    Overload Capacity
    Optional
    General Specifications
    Flexible Battery Option
    No
    Isolation Transformer
    Optional
    Paralleling Options
    Not Available
    Input Specification
    Input Voltage
    208 230 Volt
    Other Input Voltage
    176 Or 280 Volt
    Input Phase
    1 Phase
    Other Input Phase
    1 Or Phase
    Input frequency
    50/60Hz +/- 3 Hz
    Input Voltage Range (Output Derated)
    280 - 300 Volt
    Input frequency Range
    50 - 60 Hz
    Input Power Factor
    > 0.99
    Input Connections
    Hard Wire 3 wire (1PH+N+G)
    Batteries & Runtime
    Battery DC Bus
    96 - VDC
    Maximum Charger Capacity
    1 Amp.
    Battery Position Option
    Internal
    Battery Type Compatibility
    SMF / Flooded Batteries
    Batteries Recharge Time upto 90%
    < 3 Hrs.
    Communication & Management
    Control panel
    Graphical LCD Display
    SNMP Management
    Optional
    Power Management Software
    Optional
    Audible Alarm
    Audible and visible alarms prioritized by severity
    Audible noise at 1 meter from surface of unit
    < 62 Decibal
    Physical
    Maximum Height
    214 Mm
    Maximum Width
    144 Mm
    Maximum Depth
    336 Mm
    Net Weight
    9.5 Kg
    Colour
    Black
    Environmental
    Operating Temperature
    0 - 42 °C
    Operating Relative Humidity
    0 - 95 % Rh
    Operating Elevation
    0 - 1000 Meters
    Storage Temperature
    25 - 55 °C
    Other Specifications
    Technology
    Double Conversion Online
    Surge Protection
    Yes

    Documentation

    Item Catalogue
    krykard_make_online_ups
    pdf

    Options

    Related Products

    Contact Us