whatsapp
Brand Socomec UPS System On Line UPS Socomec Make 10 KVA On Line UPS

Socomec Make 10 KVA On Line UPS

ITY-E-TW100LB

UPS System On Line UPS

Price: 80830

MRP 125080 You save 44250

Affordable and reliable protection for sensitive IT and electrical applications The solution for • Professional workstations • Industrial automation • Security systems • Telecom systems • Banking ATM systems Advantages Best electrical protection • True online double conversion technology (VFI) assures high availability and total load protection. • Constant output voltage and frequency regulation makes ITYS E compatible with different applications, operating environments and GenSets. • Automatic bypass supplies the loads in the event of overloads or faults. Robust and versatile • Compact tower UPS system saves space in the operating environment. • No particular configuration on first startup. • Easy connections via IEC 320 sockets or terminals. • Wide input voltage tolerance limits the switchovers to battery mode prolonging the battery life. • Manual bypass for periodic or emergency maintenance.


Reset default

Specification

Output Specification
Output Capacity (KVA )
10 KVA
Output Capacity (KW )
8 KW
Output Power Factor
0.8 Power Factor
Output Phase
1 Phase
Other Output Phase
Or Phase
Output Voltage
230 Volt
Other Output Voltage
220 Or 240 Volt
Efficiency at Full Load
>90 %
Output Voltage Distortion
< %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
<3 %
Transfer Time
<0 ms
Output Waveform type
Sine Wave
Output Connections
Hard Wire 3 wire (1PH+N+G)
Bypass
Internal Bypass (automatic & manual)
UPS Parallel Upto
No
Overload Capacity
150% for 1 minute 125% for 10 minutes
General Specifications
Flexible Battery Option
No
Isolation Transformer
Optional
Paralleling Options
Not Available
Rack Mounting Kit
Not Available
Paralleling Kit for Synchronising
Not Available
Input Specification
Input Voltage
230 Volt
Other Input Voltage
220 Or 240 Volt
Input Phase
1 Phase
Other Input Phase
Or Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
110 - 300 Volt
Input voltage range for main operations
160 - 300 Volt
Input frequency Range
- Hz
Input Power Factor
>0.99 None
Input Connections
3-Pin 6A Indian Socket
Input Protection
Thermal Circuit Breaker
Batteries & Runtime
Approved Battery Capacity (AH)
Battery DC Bus
240 - VDC
Maximum Charger Capacity
6 Amp.
Battery Position Option
External
Battery Type Compatibility
SMF Battery
Batteries Recharge Time upto 90%
<10 Hrs.
Communication & Management
Control panel
Multi-function LCD status and control console
SNMP Management
Optional
Power Management Software
In-Built
Interface Port(s)
Audible Alarm
Audible and visible alarms prioritized by severity
Audible noise at 1 meter from surface of unit
<55 Decibal
Physical
Maximum Height
450 Mm
Maximum Width
190 Mm
Maximum Depth
320 Mm
Shipping Height
Mm
Shipping Width
Mm
Shipping Depth
Mm
Net Weight
16 Kg
Shipping weight
Kg
Rack Height(U)
U
Colour
Black
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 % Rh
Operating Elevation
0 - 1000 Meters
Storage Temperature
- °C
Storage Relative Humidity
- % Rh
Storage Elevation
- Meters
Compliances
Compliance
Compliant
Approvals
BIS
Other Environmental Compliance
Compliant
Other Specifications
Technology
Double Conversion Online
Filtering
Surge Protection
Yes

Documentation

Item Catalogue
Socomec ITYS Series Broucher